본문바로가기

FC-280 / FM-380 (TYLAN)

Mass Flow Controller

Designed to meet the exacting requirements of semiconductor processes and equipment, the Tylan FC280SA and FM380SA models are premium quality elastomer-sealed mass flow controllers and meters. These MFCs combine proven components and techniques with innovative concepts in both mechanical and electrical design.

Features & Benefits

Feature
Accuracy
Fast setpoint response
10 sccm to 30 slpm N2
0 – 5 VDC signals
Resistant to contamination clogging
Adjustable, normally – closed solenoid valve
Corrosion resistant materials

● Accuracy - Tylan General’s thermal differential flow sensor provides highly accurate And repeatable mass
   measurement of gas flow. Because the sensor measures the mass flow of gas, it is independent of
   pressure and temperature changes. This ensure that flows are consistent in different systems or locations.
● Fast setpoint Response Time - The flow sensing circuitry in the FC-280SA provides response to setpoint
   changes as fast as 0.5 seconds, which is crucial for short process cycles. The settling time to 2% of setpoint is    less than tww seconds.
● Temperature Coefficients - Maintains tight control in varying temperatures
● Balanced Power Load - Low lead current eliminates signal differing from its controlling device
● Power Operation - Insensitive to power supply variations, and will operate within ± 12 volts to ± 18 volts
● Standard Design - Industry standard pinouts and dimensions

Dimensions


FC280-1.jpg


Specifications

Performance
● Full Scale (N2 equivalent) : 10 sccm – 30 slpm
● Shutdown : 2% full scale
● Step Response Time : 1 sec (dependent on step request and conditions)
● Accuracy : ± 1.0% full scale
● Linearity : ± 0.5% full scale
● Repeatability : ± 0.2% full scale
● Pressure Coefficient : 0.00001% per bar, 0.007% per psi (typical)
● Temperature Coefficient : 0.1% per °C full scale (zero and span)
● Attitude Sensitivity : < 0.25% @ 90° C

Mechanical
● Valve : normally-closed solenoid
● Materials : 316L stainless steel, 446 stainless steel, PFA Teflon®
● Elastomers Available : Viton®, Kalrez®, Neoprene
● Leak Integrity :
   1 x 10-9 atm-cc per sec (He) inboard
   <2% full scale with Teflon poppet (normally-closed)
   <5% full scale with Teflon poppet (normally-open)
● Weight : 0.98 Kg (2 lb)

Electrical
● Supply Voltage : ± 12 VDC to ± 18 VDC
● Supply Current : 150 mA nominal
● Power Consumption : 3.3 watts @ ± 15 volts
● Input/Output Signal : 0-5 VDC

Environmental
● Operating Temperature : 5 – 50° C (ambient and gas)
● Humidity : 0 – 95% RH, non-condensing
● Maximum Inlet Pressure : 11.5 bar (150 psig)
● Differential Pressure : Nominal, 0.7 – 2.8 bar (10-40 psid)

Note: In accordance with SEMI Standard E12-91, Standard Temperature is 0° C
and Standard Pressure is 760 mm Hg (14.7 psia).